REXROTH力士乐伺服器维修各类故障,有显示无输出维修、报警维修。电源跳闸,黄灯不亮,炸模块,无输出,输出电压低,输出点无输出,红色灯亮,启动无反应,不能启动维修、开关电源损坏维修等等故障,REXROTH力士乐伺服器维修故障处理:故障代码:C0270,故障描述:电机编码器数据读取错误,对策:电机编码器回路故障,检查可能出现的三个地方:电机编码器,反馈线及CSB的编码器反馈口故障代码:C0285故障描述:电机的型号参数P-0-4014有误.对策:确认电机型号及编码器的型号(P-0-4014)。检查可能出现的三个地方:电机编码器,反馈线及CSB的编码器反馈口,故障代码:E2074
F2076 C0210 C0220 C0271故障描述:一些相关的编码器故障报警,故障代码:C0201,故障描述:"无效的参数,当切换到操作模式P4时,内部的参数被检测,有参数超出它定义的范围时就出现该报警.对策:查看S-0-0022参数,该参数包含所有的无效参数,再更改无效参数(02,03版固化软件)(2)查看S-0-0423参数,该参数包含所有的无效参数,再更改无效参数(04版固化软件)通常加载基本参数后,导入备份参数可以解决此问题,故障代码:E8260,故障描述:扭矩过载,对策:减小加速度,增大相应的限制值S-00082,S-0-0083,S-0-0092,P-0-109,优化速度环参数,增加外接制动电阻
REXROTH力士乐伺服器维修:REXROTH
DRIVE:IndraDriv
EC-HCS02:HCS02.1E-W0012-A-03-NNNN,HCS02.1E-W0012-A-03-NNNV,HCS02.1E-W0028-A-03-NNNN,HCS02.1E-W0028-A-03-NNNV,HCS02.1E-W0054-A-03-NNNN,HCS02.1E-W0054-A-03-NNNV,HCS02.1E-W0070-A-03-NNNV,HCS02.1E-W0070-A-03-NNNN;IndraDriv
EC-HCS03:HCS03.1E-W0070-A-05-NNNV,HCS03.1E-W0070-A-05-NNBV,HCS03.1E-W0100-A-05-NNNV,HCS03.1E-W0100-A-05-NNBV,HCS03.1E-W0150-A-05-NNNV,HCS03.1E-W0150-A-05-NNBV,HCS03.1E-W0210-A-05-NNNV,HCS03.1E-W0210-A-05-NNB
专业伺服电机线圈更换维修 专业伺服电机编码器维修 专业伺服电机转子维修 专业伺服电机刹车维修 专业伺服电机轴承维修 专业伺服电机密封圈维修 专业伺服驱动器进油故障维修 专业伺服电机调试 专业伺服电机安装 专业伺服电机售后 专业伺服马达维修 专业伺服电机/马达保养维修 专业伺服电机/马达磁钢更换维修 专业伺服电机编码器定位调整 专业伺服电机/马达编码器零位调试
转载请注明出处:上海仰光电子科技专业伺服驱动器维修,伺服电机维修
本文链接:http://www.shygdz.com/fuwu/Services_Show1874.htm
伺服驱动器维修 伺服电机维修 触摸屏维修 变频器维修
电话:021-50157782
手机:13817011982 微信同号
邮箱:shygdzi@163.com
联系人:张工
网址:http://www.shygdz.com
【 我们确保修好测试好给客户!!!!】
下一篇:泰克TPS2000系列示波器黑屏,无法正常启动专业维修